The C 48:4 is the second largest amplifier in the C Series family, delivering an impressive 4 × 1200 W at 4 ohms. The exceptional power output plus a long list of protection and monitoring features are all packed into a 2U chassis.
C Series amplifiers are uniquely capable of adapting to a wide variety of demanding load conditions. Each channel has an individually configurable Voltage Peak Limiter (VPL), which allows the output to be optimized for any loudspeaker load – whether a single large subwoofer or a series of small 100/70 V loudspeakers. VPL works in combination with adjustable input gain to achieve maximum headroom regardless of input levels or output impedances.
Every C Series is ready for the NomadLink® network right out of the box. With NomadLink, key amplifier parameters are displayed via DeviceControl software, and remote control of channel mutes and power on/off is under network control.
•• ower density – Total output of 4800 W (4 ohms) in a 2U cabinet
•• Four channels – All channels bridgeable for 2- or 3-channel configurations
•• Lo-Z or Hi-Z (70 V / 100 V) – Selectable per channel, normal or bridged
•• Patented Class TD amplifier topology
•• Voltage Peak Limiter (VPL) – Configurable per channel to optimize each output for connected loads
•• Phoenix-type input connectors
•• Screw terminal output connectors
•• Comprehensive protection and warning – Excessive output current, DC, high temperature, very high frequency (VHF), short
circuit, open load, mains fuse protection, and soft start
•• Efficient and uniform Intercooler® cooling
•• NomadLink® network ready
Number of channels 4
Peak total output all channels driven 4800 W
Peak output voltage per channel 141 V
Max. output current per channel 17.5 Arms
Max. Output Power 16 ohms 8 ohms 4 ohms 2 ohms Hi-Z
Per ch. (all ch.’s driven) 625 W 1000 W 1200 W 600 W 900 W (70 Vrms / 100 V peak)
Bridged per ch. 2000 W 2400 W 1200 W n.r. 1800 W (140 Vrms / 200 V peak)
Performance with Gain: 35 dB and VPL: 100 V
THD 20 Hz - 20 kHz for 1 W <0.1%
THD at 1 kHz and 1 dB below clipping <0.05%
Signal To Noise Ratio >112 dBA
Channel separation (Crosstalk) at 1 kHz >70 dB
Frequency response (1 W into 8 ohms) +0/-3 dB 6.8 Hz - 34.2 kHz
Input impedance 20 kOhm
Input Common Mode Rejection, CMR 50 dB
Output impedance @ 100 Hz 30 mOhm
Voltage Peak Limiter (VPL), max. peak output
VPL, selectable per ch. 3) 141, 118, 100, 85, 71, 59, 50, 42 V
VPL, when bridged 3) 1) 282, 236, 200, 170, 142, 118, 100, 84 V
Voltage Peak Limiter mode (per ch.) Hard / Soft
Gain and Level
Amplifier gain selectable (all channels) 1)
– rear-panel switches
23, 26, 29, 32, 35, 38, 41, 44 dB
Default gain 35 dB
Level adjustment (per ch.) Front-panel potentiometer, 21 position detented from -inf to 0 dB, hidden behind security panel/dust filter grille
Connectors and switches
Input connectors (per ch.) 3-pin Phoenix, electronically balanced
Output connectors (per ch.) Barrier strip 2-pole screw terminals
Output bridge mode A+B and/or C+D, inputs A and C are input source
NomadLink® network On board, 2 x RJ45 connectors
Intelligent fans (on/off) Yes, depending on presence of output signal
Power on/off and Remote enable on/off Individual switches on front-panel
Cooling Two fans, front-to-rear airflow, temperature controlled speed
Front-panel indicators
Common NomadLink® Network; Power Average Limiter (PAL) 2); Power on
Per channel
Signal present / High-impedance; -10 dB and -4 dB output signal; Voltage Peak Limiter (VPL); Current Peak Limiter (CPL);
Very High Frequency (VHF); High Temperature; Fault; Mute
Power
Operating voltage, 230 V / 115 V nominal 130 -265 / 65-135 V
Minimum power-up voltage, 230 V / 115 V 171 V / 85 V
Power Average Limiter (PAL) 2) Yes
Soft start / Inrush Current Draw Yes / max. 5 A
Mains connector 230 V CE: 16 A, CEE7; 115 V ETL: 20 A / NEMA 5-20P
Dimensions (W/H/D) W: 483 mm (19”), H: 88 mm (2 U), D: 343 mm (13.5”)
Weight 12 kg (26.4 lbs.)
Finish Black painted steel chassis with gray painted steel front
Approvals CE, ANSI/UL 60065 (ETL), CSA C22.2 NO. 60065, FCC
Note 1): Automatic -6 dB gain compensation when bridging channels. Ch.’s A+B and/or C+D, can be bridged individually.
Note 2): PAL can reduce the maximum output power to keep the power supply operating safely, and/or to prevent excessive current draw tripping the mains breaker.
Refer to Operation Manual.
Note 3): For sine waves, peak voltage output values translate to Vrms with the formula V/1.41 = Vrms. E.g. 100 V peak equals app. 70 Vrms.
Hence, outputs can be set for high-impedance loads without requiring a transformer.
All specifications are subject to change without notice.